44 2033180199
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.
Journal of Phlebology and Lymphology

Sign up for email alert when new content gets added: Sign up

Great saphenous vein diameter at different regions and it's relation to reflux

Author(s): Said EL Mallah , Mohammed AL-Khateep, Hady Kamel

Background:Great saphenous vein incompetence is involved in the majority of cases of varicose disease. Standard pre-interventional assessment is required to decide the treatment modalities. GSV diameter measured at sapheno-femoral junction, Proximal thigh, Distal thigh, Knee, Proximal leg, Distal leg. Analysis done to find at which diameter size the reflux expected to occur. Methods:Study involved 100 limbs from outpatient vascular clinic, GSV diameter measurement at the sapheno-femoral junction, at the proximal thigh, at the distal thigh, below the knee, mid leg in correlation to reflux. Results:SFJ reflux (group I) at 7.16 ± 2.30 mm, proximal thigh (group II) at 6.60 ± 1.89 mm, distal thigh (group III a) at 6.12 ± 1.63 mm, knee (group III b) at 5.78 ± 1.60 mm, proximal leg (group IV) at 4.6 ± 1.24 mm, and mid leg (group V) at 3.59 ± 1.16 mm. Conclusion:Measurement at six sites revealed higher sensitivity and specificity to predict reflux, GSV diameter correlates with reflux, Sites to predict reflux not only at SFJ and Proximal thigh but GSV measurement at knee joint can predict reflux. Measurement of GSV at knee joint can predict reflux if more than 5.5 mm.


PDF
 
Google Scholar citation report
Citations : 141

Journal of Phlebology and Lymphology received 141 citations as per Google Scholar report

pulsus-health-tech
Top